- The key and important parts with tensile strength greater than 1034Mpa should be relieved of stress at 200±10℃ for more than 1 hour before plating, and the carburized or surface hardened parts should be relieved of stress at 140±10℃ for more than 5 hours. The cleaning agent used for cleaning shall have no effect on the binding force of the coating and no corrosion on the substrate. Acid activation Acid activation solution should be able to remove corrosion products and oxide film (skin) on the surface of parts without excessive corrosion on the matrix.
Bridge protection system generally do not need to be specially installed special drainage system, the use of hexagonal mesh made of gabion mesh boxes, the inside of the filler are selected stones, these stones are not easy to wear, and between the stones and stones will retain some gaps, so it is very good to meet the drainage requirements.
- Packing is also very important. The cut wire should be bundled and tightly packed with plastic film, and then placed in a regular box. The whole box should be filled and sealed. It is better not to have half a box.
Post time: 08-10-22
Post time: 10-10-22- Galvanizing can be done by zincate galvanizing or chloride galvanizing. Appropriate additives should be used to obtain a coating that meets the requirements of this standard. Light treatment should be carried out after light plating. The parts that need to be dehydrogenated for passivation should be passivated after dehydrogenation. Before passivation, 1%H2SO4 or 1% hydrochloric acid should be applied for activation for 5~15s. Passivation shall be treated with colored chromate unless otherwise specified in the design drawings.
Post time: 18-07-22
Post time: 09-01-23
Post time: 06-03-23Steel wire mesh by its own unique advantages in the construction profession, reinforcement anti-crack occupation is indispensable reinforcement anti-crack data, high degree of product error is small, mesh mesh uniform, solid welding, strong acceptance, not easy to deformation, steel wire mesh in different fields have different called, in bridge engineering construction people call it soft reinforcement.
- 2, the smelting process of the production enterprise will also affect the corrosion resistance of stainless steel.
High quality galvanized wire in general, the zinc layer attached to the surface of the wire is relatively thick, so when we buy galvanized wire, as long as we look at the thickness of the zinc layer machine, we can generally judge whether the quality of galvanized wire is high quality.
- Hot dip galvanizing is also called hot dip zinc and hot dip galvanizing: it is an effective way of metal anticorrosion, mainly used in various industries of metal structure facilities. It is to immerse the steel parts after rust removal into zinc solution melted at about 500℃, so that the surface of the steel members is attached with zinc layer, so as to play the purpose of anticorrosion.
If the coating roughness is not caused by the above reasons, it may be caused by impurities in the plating solution. Can take a small amount of electroplating solution, filtration test, and then take a small amount of electroplating solution, with zinc powder treatment after the test, check the problem is solid particles or copper, lead and other foreign metal impurities caused by. One by one, it’s not hard to find the cause of the problem. Galvanized iron wire coating blister, poor adhesion.
Galvanized hexagonal net is a kind of galvanized metal wire mesh, mesh shape is hexagonal.
There are three methods to detect the thickness of zinc layer of galvanized wire: weighing method, cross section microscopy method and magnetic method, among which the first two experiments will cause certain damage to galvanized wire, including the length of galvanized wire and the reduction of dosage. The general detection of galvanized wire galvanized layer is detected by magnetic method, which is also a more intuitive and convenient method. The standard of galvanized layer thickness is related to the wire diameter of galvanized wire. The larger the wire diameter of galvanized wire, the thicker the galvanized layer is. It is the thickness of galvanized layer and cast iron after centrifugal separation.
- The smaller the mesh of decorative hook mesh, the finer the demand wire, the larger the mesh, the thicker the demand wire. For example, 6.5cm mesh aperture, the required iron diameter is 3.5mm-4mm. Then a fine welding will be broken, and then thick and heavy, workers can not bear.
The temperature of large roll galvanized wire should be controlled at 30 to 50℃ during electroplating. Because the chloride ions in the bath are very corrosive, quartz glass heaters are generally used. Continuous production does not need heating, but needs cooling. Cooling can be in the groove side row thin wall plastic pipe, through the flow of tap water cooling, can also be used as a titanium pipe temperature control device.
- As for the protection operation of galvanized barbed rope column, replace the column which is corroded or misinterpreted and so on, and place the replacement area from the beginning, and reinforce the column with unstable pile foundation in time. There is also about the protection of galvanized barbed rope itself, to repair the damaged local, will be severely replaced by rust.
Post time: 21-06-22- The most obvious gap in a short time is the cross section of this piece, hot dip galvanized barbed wire because it is the surface anti-corrosion treatment, so in the cross section of this piece will appear rust, and stainless steel barbed wire because the internal raw materials and surface raw materials are consistent, so there is no such situation.
Through the maintenance of galvanized wire, it can not only greatly prolong its service life, but also improve its efficiency in the daily use process. Because the labeled electrode potential of zinc is -0.762v, which is negative than iron, zinc becomes the anode when the galvanic cell is formed after being corroded by the medium. It itself is dissolved to protect the steel matrix. The duration of the protection of galvanized wire layer has a great relationship with the thickness.
- First of all, we need to understand that the electrical conductivity of the wire depends on its material and size, and is not affected by the surface treatment method. Whether galvanized treatment or wire drawing treatment, they are the surface of the steel wire treatment, will not change the basic physical properties of the steel wire, electrical conductivity will not be affected. Therefore, in theory, the galvanized wire drawing treatment should not have any effect on the electrical conductivity of the steel wire.
- 2. The cage must be strong
(1) In the painting construction should pay attention to ventilation, moisture-proof, fire prevention. The working environment and painting tools should be kept clean, the pressure of the air pump should be controlled within 0.63MPa, and the safety valve should be checked for failure.
- Because the size of the plane or the surface of the urban area is relatively small, many sports arenas are built in the more prosperous and lively sections, with hexagonal nets to protect the barrier, so it greatly reduces the spherical three-dimensional flying out of the field so affect the traffic order of the bad things.
The number of each bundle of the blade barbed rope is 50, which is reduced by hydraulic compression and thus more convenient for loading and unloading. The forklift can load and unload easily. Under normal circumstances, when the export will be packaged and sold, so that the volume occupied in the container is relatively small, it can be easily placed and will not take up much space.
Galvanized wire mesh is divided into hot dip galvanized wire mesh and cold galvanized wire mesh. Galvanized steel wire net selects the high quality low carbon steel wire, iron wire factory made by precision of automation machinery welding technology processing, smooth surface, firm structure, integrity is strong, even if the local cutting of galvanized steel wire net, or local also under pressure from loose phenomenon, after molding, wire mesh galvanized corrosion resistance good, has the advantage that the general steel mesh does not have.
- 6. The barbed rope protective net should be laid according to the terrain of the road boundary. The flat section should be set horizontally, and the slope section should be set along the slope or by the step form.
- 4, the material requirements of the silk: change wire braid, electric galvanized wire braid, hot galvanized wire braid, first braid after hot plating.
The application of cold wire drawing is very wide today. What problems need to be paid attention to in the acceptance of cold wire drawing in galvanizing plant?