Post time: 12-07-22Barbed rope factory not only provides the sales of blade barbed rope, including the subsequent construction is also contracted, and the construction price is particularly different.
- ② Electric galvanized shaft wire direct selling shall not be used for waist hoop compression reinforcement, usually not used for all binding.
Post time: 23-11-22- To stop normalizing or soxhlet processing of wire rod, spheroidization annealing is used instead of large specification. In the middle, especially before the waste drawing process, the thermal disposal of soxhlet is widely used. Prevent decarbonization during thermal disposal. After hot disposal, sulfuric acid or hydrochloric acid pickling is used to remove the iron sheet. Coating can be used to dip lime, phosphating, borax treatment or copper plating.
Wire factory reminds you in the purchase of galvanized wire, should be stored in dry, ventilated conditions, do not contain corrosive gases, do not mix with organic volatile gas produced paint, plastic and other substances in a good environment. If possible, we can add reliable inner packaging for galvanized parts, and put desiccant. If the zinc layer of white spots and long hair, can only be removed by mechanical methods, and then normal passivation, or completely washed off the zinc layer after re-plating.
Post time: 07-11-22- 4. When cleaning the cage, remember not to brush violently, but pay attention to the strength. Otherwise easy to damage the surface of the paint layer.
- The drawing process of the product drawing process has a great influence on the product function. Generally, a large total surface reduction rate of about 90% (see area reduction rate) and a small pass surface reduction rate (about less than 23%) are selected to ensure the endurance of the product. On the high strength spring steel wire, drawing should control the exit temperature of each passage of the steel wire is lower than 150℃, to avoid the steel wire due to strain aging and appear to change the crack, which is the formation of steel wire scrap the primary disadvantage.
Cold galvanizing (galvanizing) is in the plating tank after the current unidirectional, so that the zinc gradually plated on the metal surface, slow production speed, uniform coating, thin thickness, usually as long as 3-15g, bright appearance, poor corrosion resistance, usually a few months will rust. Compared with hot dip galvanizing, the production cost of electric galvanizing is lower.
Crevice corrosion is a kind of corrosion in small area, especially in concealed position, which can form vicious corrosion cycle. Almost all the crevice corrosion can occur in a metal alloy, with gas containing active anionic neutral medium Z is easy to cause crevice corrosion, crevice corrosion often occurs in the aperture of 0.025 to 0.1 mm, because of long time gathered, the cracks will exist a series of impurities, coupled with the external environment of damp easily corrode the area of the gap is small.
Post time: 21-02-23Its specific design layout principle is:
4, when the greenhouse special electric galvanized shaft wire from the well and winding to the roll, be sure to clean up the well fluid, mud sand and other things stuck on the wire, and also coated with protective oil.
The main difference between the two is the carbon content. The carbon content of iron is 2.11 percent or greater, while the carbon content of steel is 2.11 percent or less. The iron carbon alloy with carbon content above 2.11% is cast iron (pig iron), which is basically not malleable and cannot be drawn into wire. Secondly, the content of impurities is different. The content of harmful impurities such as sulfur and phosphorus in steel is smaller. Steel wire general color focus, iron wire color light point, white point.
With the technique of preventing the coating from peeling off the hook mesh, hook tennis court chain link fence systems have long tended to define lines that economically attach amenities and add value to the property. The interlocking system also allows deductions for easy attachment control.
Post time: 31-10-22- Heavy hexagonal mesh can be used for slope support, mountain rock face hanging net shotcrete, slope planting green, it can also be made of stone cage cage, stone pad cage, for rivers, DAMS and seawall prevention and control of erosion and reservoirs, river interception with stone cage.
The best way to manage off-road safety is to carry out management and protection from the source, maximize the safety of people’s lives and property, and reduce the non-operational costs of railway enterprises, which is a key content of railway safety work in the new era. At this time, it is necessary to install protective nets on both sides of the railway, which is what we usually say, blade barbed rope protective nets, which can prevent accidents.
- 1. Choose according to the size of your dog
Hexagonal mesh is also known as twisted mesh, insulation mesh, soft edge mesh. It is made of a single mesh reel. The mesh, mesh, galvanized and PVC coated properties are the same as the cage. This product can be different shapes, sizes of the stone into the alloy net to form a flexible whole, can be lifted, cars, shipping to the L place, the alloy net connected into a larger whole, the construction of throwing convenient, fast, good economic performance.
- 2, galvanized wire mesh molding sheet storage ground should be flat, according to the symbolic requirements of the accumulation of regular, height should not exceed 2M, and away from heat sources, avoid exposure.
- 5, there are no special requirements: such as whether to shrink packaging, etc.
- Hot dip galvanizing, also known as hot dip galvanizing, is a method of obtaining a metal covering by immersing a steel member in a molten zinc solution. With the rapid development of high-voltage transmission, transportation and communication, the protection requirements for steel parts are becoming higher and higher, and the demand for hot-dip galvanizing is also increasing. Usually the thickness of electric galvanized layer is 5 ~ 15μm, and the large roll galvanized wire layer is generally more than 35μm, even up to 200μm. Hot dip galvanizing has good covering ability, dense coating and no organic inclusions.
The wire rod should be normalized or soxhlet processed, instead of spheroidal annealing for standard large ones. Soxhlet process is widely used in the heat treatment of the center, especially the products before drawing. Avoid decarbonization during heat treatment. After heat treatment, sulfuric acid or hydrochloric acid pickling is used to remove iron sheet. The coating (see smooth carrier) can be dip-lime, phosphating, borax treatment or copper plating.
To remove surface active substances by matting with activated carbon. Or filtration to make the foam less stable, which are effective measures; Other measures should also be taken to reduce the amount of surface-active substances brought in to Z. The electroplating speed can be significantly reduced by the introduction of organic matter. Although the chemical formula is conducive to a high deposition rate, the coating thickness cannot meet the requirements after the organic matter is loaded, so activated carbon can be used to treat the tank.